Quality control of cement strength is dependent on the characteristics of the standard mortar, particularly sand gradation and mixture proportions. This study aimed to investigate the effect of sand gradation on the fresh and hardened properties of standard mortar and to evaluate the suitability of locally produced silica sand for cement quality control tests. For this purpose, silica sands conforming to the gradation requirements of ASTM C778 and EN 196-1, along with imported standard sand from Germany conforming to EN 196-1, were used to prepare standard mortars based on the mixture proportions specified in ASTM C109 and EN 196-1. The results showed that the interparticle void content of the ASTM C778 sand in the loose state was 36.48%, compared with 28.87% for the EN 196-1 sand. Consequently, the mortar containing ASTM sand lacked sufficient paste to fill the voids between the sand particles, resulting in a reduction of more than 50% in the 28-day compressive strength. Moreover, the mortar exhibited a dry and non-cohesive spread in the flow table test. In contrast, although the workability of the mortar containing locally produced sand conforming to EN 196-1 was slightly lower, its 28-day compressive strength was comparable to that of the imported sand, ranging from 39.6 to 41.2 MPa, compared with 39.5 MPa for the imported sand. Therefore, locally produced silica sand conforming to EN 196-1 can be considered a suitable alternative to imported standard sand for cement quality control testing in Iran.